I tried the process in the Intellitouch manual to read the 520164 firmware (press buttons 2 and 4 simultaneously but it gives me the Error Retrieving Data note. I7 firmware is 1.16 (per the Screenlogic program) Is the latter situation plausible, that either the 520164 or i7 have incompatible firmware versions?

#Pentair control panel not commanding pumps update#

Continues to give 'Error Retrieving Date' message when Program button is selected, however, does continue to update with correct status of outdoor temp and pool temp, running status of equipment, etc.Īll signs point to either a bad port on the indoor board or there is a firmware mismatch between the indoor and outdoor boards.

pentair control panel not commanding pumps

Tested continuity of all port wires from i7 connector to back of 520164. Being a controls guy, this is not preferable, however, it seems to work as only one device talks at a time.Ĭomport 2 - Indoor control panel Pentair part number 520164, Version either 1019, 1619 or 1819, second number hard to read.

#Pentair control panel not commanding pumps serial#

I have 3 items connected to 2 serial ports.Ĭomport 1 - Screeenlogic and VSF pump. if you're able to measure the dc current draw and you get much more than 180mA with backlight and leds at 100%, then it's probably got a blown comm portĭetails of testing. if #2 fails then there could be a problem with your indoor panel. if #1 checks out, try connecting only your indoor panel to the outdoor board with a short "known good" length of cableģ. Using a multimeter to check continuity would be useful.Ģ. Shut the power off to everything and inspect the comm port pins/terminal block for corrosion and see whether there's a good solid connection. That isn't to say you don't have an actual hardware problem now, but I'd start on the "bad/loose connection" path.ġ. I have a light schedule set to 7PM to 10PM. I have the Cleaner schedule set of 10AM to 2PM. In Settings, I have Solor enabled and heat pump set to no. I have 'Heat' set to Solar and the temp set well above what the pool is actually. i check out to replace the screen i need to replace the entire drive kit which costs 600.00. It follows the start time but not the end time. Pump works fine in pool mode, but shuts off when we hit the Spa button on the Pentair intellitouch 520138 control panel. Auto valves move correctly, and the heater turns on, but no pump to circulate the water.

pentair control panel not commanding pumps

I cannot program anything since i cant see what it is i am programming. Hi, everything was working fine up until about a week ago, when we noticed that the pump would not turn on when we switched to spa mode. I just noticed that the LCD screen is blank. but, if installing the screenlogic "fixed" the indoor unit, I'd guess that the indoor unit wasn't actually broken and the mere act of adding extra wires to the comm port terminal block for screenlogic did the trick (there was likely some dirt/grit/loose connection on the comm port connector?). I have had my Pentair intelliflo VS pump just over 2 years now. I can't tell whether you have an i5 (with a single comm port plug) or an i7/i9 (two comm port plugs). Ill shut off the IC40 chlorinator during the dispense, just like the native control board. Ill start a recurring programmable timer to dispense a programmable amount of acid, just like the factory board. is it just the indoor panel that has a problem)? Basically, Ill design a unit that wakes up when power is supplied by the mother Pentair control panel, and then times the events.

  • Controls filter and pump functions, plus 3 additional pieces of equipment, allowing you control of up to 4 operating schedules or programs.Can the screenlogic and your VSF pump still talk to the outdoor board (e.g.
  • The EasyTouch Indoor Control Panel is designed to be used with the EasyTouch 8 or EasyTouch 4 system.

    #Pentair control panel not commanding pumps full#

    These systems work with the ScreenLogic2® Interface for full control via computer or mobile devices. EasyTouch Indoor Control Panel Overview EasyTouch Indoor Control Panel The EasyTouch Indoor Control Panel provides you with one touch automatic control for all of your pool and spa daily operations from inside your home. The EasyTouch PL4 system is designed for a single body of water, while the EasyTouch PSL4 system is designed to control a pool and spa combination. EasyTouch PL4 and PSL4 control systems provide economical yet sophisticated control over filtration, pumps, lighting, chemical management and more.